| New and Interesting Products |
|
|
|
|
|
|
|
|
|
|
|
|
| USB Power Meter from 80 MHz to 18 GHz | |
Power Meter
from ETS-Lindgren
|
| The 7002-004 from ETS-Lindgren is a USB-Based Power Meter that operates from 80 MHz to 18 GHz. It is designed to conduct accurate CW and pulsed RF power measurements for automotive, military, telecom and EMC testing applications. This power meter has a power measurement range from -45 dBm to +10 dBm and has a power accuracy of ±0.25 dB. |
|
Download Datasheet
Product Details | |
|
|
|
|
|
|
|
|
| 25, 50, 100, 150, or 250 MHz Arbitrary Function Generators | |
EMI Signal Generator
from Tektronix, Inc.
|
| The AFG31000 Series from Tektronix are Arbitrary Function Generators have output bandwidths of 25, 50, 100, 150, or 250 MHz. They support multiple built-in waveforms, including sine, square, ramp, pulse, noise, & other frequently used waveforms, and have a sample rate of 250 MSa/s, 1 GSa/s, or 2 GSa/s. |
|
Download Datasheet
Product Details | |
|
|
|
| ESD Simulator from 5 V to 8 kV | |
ESD Simulator
from Electro-Tech Systems
|
| The Model 9910 PinPulse from Electro-Tech Systems is an ESD Simulator that generates parasitic-free waveforms over a voltage range of 5 V to 8 kV. It supports 3 built-in ESD models: HBM, HMM & MM and has programmable polarity and voltage stepping. This simulator can serve as a manual two-point ESD simulator ideal for low pin count devices and generates all waveforms in compliance with current JEDEC & ESDA standards. |
|
Download Datasheet
Product Details | |
|
|
|
| 50/60 Hz Magnetic Field Generator from 1 A/m to 100 A/m | |
Magnetic Field Generator
from Com-Power Corporation
|
| The APF-5060 from Com-Power Corporation is a Magnetic Field Generator that has an output frequency of 50 or 60 Hz. It can generate a magnetic field of strength from 1 A/m to 100 A/m and an output current of 120 A. This generator has a harmonic distortion of less than 8% and a coil factor of 0.01 to 99.99. |
|
Download Datasheet
Product Details | |
|
|
|
|
|
|
|
|
|
|
| Coupling Decoupling Network from 150 Hz to 230 MHz | |
Coupling Decoupling Network
from Schwarzbeck Mess - Elektronik OHG
|
| The CDN M1 16A 1000V from Schwarzbeck Mess-Elektronik OHG is a Coupling Decoupling Network (CDN) that operates from 150 Hz to 230 MHz. It is designed to inject common-mode disturbance signals into unscreened AC and DC power supply lines (mains) to facilitate conducted immunity testing as per the IEC 61000-4-6 standard. This network can handle an input power of up to 6 W (continuous), provides a test voltage of up to 30 V, and has a voltage division factor of 9.5 dB (RF input to equipment under test (EUT) port). |
|
Download Datasheet
Product Details | |
|
|
|
| Bulk Current Injection Probe from 10 kHz to 500 MHz | |
Bulk Current Injection (BCI) Probe
from TEKBOX Digital Solutions
|
| The TBBCI1-300K420-HV from TEKBOX Digital Solutions is a Bulk Current Injection Probe designed primarily for ISO 11452-4 BCI testing, GJB 151B-2013, CS114 testing for MIL-STD-461, and DO-160 section 20 testing from 10 kHz to 500 MHz. It has an insertion loss of 5 dB and a typical transfer impedance of 29 dB Ohm. This probe is capable of injecting severity levels I (60mA), II (100mA), III (150mA), IV (200mA) and customer-specific severity level V up to 350 mA. |
|
Download Datasheet
Product Details | |
|
|
|
| LISN from 150 kHz to 30 MHz | |
Line Impedance Stabilization Network
from EMC Electronic
|
| The LS032A2 from EMC Electronic is a Line Impedance Stabilization Network (LISN) that operates from 150 kHz to 30 MHz. It complies with CISPR 16-1-2 standard and provides a stable, standardized line impedance of 50 µH // 50 Ohm for the EUT for conducted emission measurements. This LISN routes unwanted RF noise generated by the EUT to the EMI receiver and prevents noise coming from the mains supply from reaching the receiver. |
|
Download Datasheet
Product Details | |
|
|
|
| Clamp-On Current Probe from 20 Hz to 50 kHz | |
Current Probe
from EM Antennas
|
| The EM-6980 from EM Antennas is a Clamp-on Current Probe that covers a frequency range from 20 Hz to 50 kHz. It consists of two semicircles that clamp around conductors by means of a clip to measure the conducted current without a direct connection to the circuit under test. This probe has a core of ferrous materials separated by an air gap to prevent erroneous measurements due to saturation and is capable of measuring signals and noise superimposed on power currents up to 300 A from DC to 400 Hz. |
|
Download Datasheet
Product Details | |
|
|
|
| Shielded Test Enclosure from 1 to 6 GHz | |
Shielded Test Enclosure
from LabiFix Innovations
|
| The LBX0500 from LabiFix Innovations is an RF Shield Box that operates from 1 to 6 GHz. It is designed for wireless device testing (e.g. 3G, 4G, 5G LTE, and Wi-Fi 802.11), R&D, pre-compliance, and over-the-air (OTA) applications requiring high RF isolation in a compact form-factor. It features a high-performance RF absorber lining, EMI filters on data and power lines and an RF gasket to minimize RF leakage and external interference. |
|
Download Datasheet
Product Details | |
|
|
|
| Reverberation Chamber from 900 MHz to 18 GHz | |
Reverberation Chamber
from GTemCell Group
|
| The 1G-RVC from GTemCell Group is a Reverberation Chamber that covers a frequency range from 900 MHz to 18 GHz. It provides shielding effectiveness against field strengths of up to 4 kV/m and can handle an input RF power of up to 250 W. This chamber is made of fully hot galvanized steel with a stainless-steel door that measures 90 x 90 cm with three rows of Knifes contacts. |
|
Download Datasheet
Product Details | |
|
|
|
|
|
| EMC Filter for Surge Protection | |
EMC / EMI Filter
from Phoenix Contact GmbH
|
| The 1316312 from Phoenix Contact GmbH is an EMC filter that is designed for protection against current surges. It has a 2-wire floating signal circuit and has a current rating of 500 mA and a voltage rating of 38 V (DC) & 30 V (AC). This filter has a response time of less than 25 ns and a capacitance (Core-Earth) of 50 nF. It is based on a push-in connection technology and measures 6.2 x 105.8 x 69.5 mm. |
|
Download Datasheet
Product Details | |
|
|
|
| EMC Pre-Amplifier from 1 to 8 GHz | |
EMC Pre-Amplifier
from TOYO Corporation
|
| The TPA0108-40 from TOYO Corporation is an EMC Pre-Amplifier that operates from 1 to 8 GHz. It provides an output power of +13 dBm with a gain of 42 dB and a gain flatness of ±1.5 dB. This Pre-Amplifier is suitable for EMI measurements above 1 GHz. It supports EMC/EMI measurement methods as specified in CISPR standards, FCC regulations of the USA, and MIL standards. |
|
Download Datasheet
Product Details | |
|
|
|
| Pyramid EMC Absorber from 0.5 to 100 GHz | |
EMC Absorbers
from Holland Shielding Systems
|
| The 3690-300 from Holland Shielding Systems is a Pyramid EMC Absorber that operates from 0.5 to 100 GHz. It is made of a microporous material to improve its power handling capacity and can withstand power irradiation (continuous wave) of 8 to 10 kW/m2. This material also supports inside and outside ventilation circulation and has good flame-retardant characteristics, having an oxygen index of more than 60% and a flame-retardant B1 level. |
|
Download Datasheet
Product Details | |
|
|
|
| Open-Ended Waveguide Probe from 0.75 to 1.15 GHz | |
Near Field Probe
from Lorentz EM Technology Co., Ltd.
|
| The ANTP01-0009N-X-111 from LoRentz is an Open-Ended Waveguide Probe that operates from 0.75 to 1.15 GHz. It is designed to sample radiated electromagnetic field of an antenna under test with lower interference between the probe and AUT. This probe has exceptional linear polarization purity, long-term stability & repeatability and a VSWR of less than 2.2:1. |
|
Download Datasheet
Product Details | |
|
|
|
|
|
|
|
|
|
|
|
|
|
| Transient Limiter with Fuse Lamp from DC to 200 MHz | |
Transient Limiter
from The EMC Shop
|
| The DPL200M from The EMC Shop is a Transient Limiter that operates from DC to 200 MHz. It has a built-in 20 dB attenuator and a fuse lamp to protect equipment when measuring high-energy spectra. This limiter protects the receiver input from excessive disturbance levels of more than 100 dBµV, whilst smaller levels can pass with a fixed attenuation of 20 dB to the receiver input. |
|
Download Datasheet
Product Details | |
|