TEM / GTEM Cells - Teseq

10 TEM / GTEM Cells from Teseq meet your specification.

Selected FiltersReset All

  • Manufacturer : Teseq
  • Teseq - GTEM 1500
    TEM / GTEM Cell from Teseq
    GTEM Cell for Emissions and Immunity Testing
    • Frequency:  DC to 20 GHz
    • Type:  GTEM Cell
    • Septum Height:  1500 mm
    • Shielding Effectiveness:  60 to 80 dB
    • EMC Standards:  IEC/EN 61000-4-20, CISPR 14-1, EN 61000-6-3, EN 61...
    • Test Type:  Emission, Immunity
    • Max input power:  1000 W
    • Max EUT Size:  1.11 x 1.11 x 0.99 m
  • Teseq - GTEM 250
    TEM / GTEM Cell from Teseq
    GTEM Cell for Emissions and Immunity Testing
    • Frequency:  DC to 20 GHz
    • Type:  GTEM Cell
    • Septum Height:  250 mm
    • Shielding Effectiveness:  60 to 80 dB
    • EMC Standards:  IEC/EN 61000-4-20, CISPR 14-1, EN 61000-6-3, EN 61...
    • Test Type:  Emission, Immunity
    • Max input power:  50 W
    • Max EUT Size:  0.2 x 0.2 x 0.15 m
  • GTEM Cell for Emissions and Immunity Testing, version for SAE
    • Frequency:  DC to 20 GHz
    • Type:  GTEM Cell
    • Septum Height:  250 mm
    • Shielding Effectiveness:  90 to 100 dB
    • EMC Standards:  IEC/EN 61000-4-20, SAE J1752/3, IEC 62132-2, IEC 6...
    • Test Type:  Emission, Immunity
    • Max input power:  100 W
    • Max EUT Size:  0.2 x 0.2 x 0.15 m
  • Test Cell for Electroacoustics - Hearing Aids IEC 60118-13
    • Frequency:  DC to 20 GHz
    • Type:  GTEM Cell
    • Septum Height:  250 mm
    • Shielding Effectiveness:  80 to 100 dB
    • EMC Standards:  IEC/EN 61000-4-20
    • Test Type:  Emission, Immunity
    • Max input power:  100 W
    • Max EUT Size:  0.2 x 0.2 x 0.15 m
  • Teseq - GTEM 500
    TEM / GTEM Cell from Teseq
    GTEM Cell for Emissions and Immunity Testing
    • Frequency:  DC to 20 GHz
    • Type:  GTEM Cell
    • Septum Height:  500 mm
    • Shielding Effectiveness:  60 to 80 dB
    • EMC Standards:  IEC/EN 61000-4-20, CISPR 14-1, EN 61000-6-3, EN 61...
    • Test Type:  Emission, Immunity
    • Max input power:  100 W
    • Max EUT Size:  0.41 x 0.41 x 0.31 m
  • Teseq - GTEM 750
    TEM / GTEM Cell from Teseq
    GTEM Cell for Emissions and Immunity Testing
    • Frequency:  DC to 20 GHz
    • Type:  GTEM Cell
    • Septum Height:  750 mm
    • Shielding Effectiveness:  60 to 80 dB
    • EMC Standards:  IEC/EN 61000-4-20, CISPR 14-1, EN 61000-6-3, EN 61...
    • Test Type:  Emission, Immunity
    • Max input power:  200 W
    • Max EUT Size:  0.62 x 0.62 x 0.49 m
  • Teseq - GTEM 1250
    TEM / GTEM Cell from Teseq
    GTEM Cell for Emissions and Immunity Testing
    • Frequency:  DC to 20 GHz
    • Type:  GTEM Cell
    • Septum Height:  1250 mm
    • Shielding Effectiveness:  60 to 80 dB
    • EMC Standards:  IEC/EN 61000-4-20, CISPR 14-1, EN 61000-6-3, EN 61...
    • Test Type:  Emission, Immunity
    • Max input power:  1000 W
    • Max EUT Size:  0.93 x 0.93 x 0.83 m
  • Teseq - GTEM 1000
    TEM / GTEM Cell from Teseq
    GTEM Cell for Emissions and Immunity Testing
    • Frequency:  DC to 20 GHz
    • Type:  GTEM Cell
    • Septum Height:  1000 mm
    • Shielding Effectiveness:  60 to 80 dB
    • EMC Standards:  IEC/EN 61000-4-20, CISPR 14-1, EN 61000-6-3, EN 61...
    • Test Type:  Emission, Immunity
    • Max input power:  1000 W
    • Max EUT Size:  0.74 x 0.74 x 0.66 m
  • Teseq - GTEM 1750
    TEM / GTEM Cell from Teseq
    GTEM Cell for Emissions and Immunity Testing
    • Frequency:  DC to 20 GHz
    • Type:  GTEM Cell
    • Septum Height:  1750 mm
    • Shielding Effectiveness:  60 to 80 dB
    • EMC Standards:  IEC/EN 61000-4-20, CISPR 14-1, EN 61000-6-3, EN 61...
    • Test Type:  Emission, Immunity
    • Max input power:  1000 W
    • Max EUT Size:  1.32 x 1.32 x 1.16 m
  • Teseq - DTEM
    TEM / GTEM Cell from Teseq
    TEM Cell for Emissions and Immunity Testing
    • Frequency:  DC to 400 MHz
    • Type:  TEM Cell
    • Septum Height:  300 mm
    • EMC Standards:  IEC/EN 61000-4-20, CISPR 25, ISO 11452-3, SAE J111...
    • Test Type:  Emission, Immunity
    • Max input power:  1000 W
    • Control Interface:  BNC, BNC - Female
1 - 10 of 10 TEM / GTEM Cells
../../1009tem_gtem_cellstem-gtem-cellsTEM / GTEM Cellsstype:expandstype:singlesfrequency:expand,sseptum_height:expand,sshielding_effectiveness:expandsfrequency:727,sseptum_height:749,sshielding_effectiveness:760sfrequency:MHz,sseptum_height:mm,sshielding_effectiveness:dB{"stype":"or","sfrequency":"or","sseptum_height":"or","sshielding_effectiveness":"or"} tem-gtem-cells 1009 ../../../../ equipments-search equipment1 ../
Need Help Finding a Product?