L1-500

Line Impedance Stabilization Network by Narda Safety Test Solutions
Download Datasheet Request Quote

Note: Your Quotation Request will be directed to Narda Safety Test Solutions.

The L1-500 from Narda Safety Test Solutions is a Line Impedance Stabilization Network (LISN) that operates from 9 kHz to 30 MHz. It complies with CISPR 16-1-2, VDE 0876, FCC Part 15, and MIL-STD- 461 F standards. This system consists of a 250 µH coil and a built-in cooling fan. It can also be stacked with up to 4 units in a wheeled rack configuration for flexibility. This LISN system can be used to couple the measuring receiver to the disturbance signal generated by Equipments Under Test (EUTs) and decouple the receiver from unwanted RF signals carried by power lines. It provides an output current of 300 A (continuous) and 500 A (for 20 min.). 

The L1-500 uses reference impedance values and phase responses to conduct accurate and repeatable measurements of disturbance voltage that EUTs may inject into the power mains. This system requires an AC supply of up to 400 V and a DC supply of 565 V. It is available in a rack-mount enclosure that measures 510 x 175 x 830 mm. This LISN system is ideal for flexible EMC test and measurement applications.

Product Specifications

Product Details

  • Part Number
    L1-500
  • Manufacturer
    Narda Safety Test Solutions
  • Description
    Line Impedance Stabilization Network from 9 kHz to 30 MHz

General Parameters

  • Applications
    Conducted Emission Testing, Power Line Disturbance Voltage Measurement, EMI Compliance Testing, AC and DC Powered EUT Testing
  • Connectors
    BNC
  • Dimensions
    510 × 175 × 830 mm
  • EMC Standards
    CISPR 16-1-2, VDE 0876, FCC Part 15, MIL-STD 461F
  • Line Impedance
    50 Ohms
  • Operating Temperature
    -10 °C to +40 °C
  • Storage Temperature
    -25 °C to +75 °C
  • Weight
    55 kg
  • AC Voltage
    Up to 400 VAC
  • DC Voltage
    DC to 565 V
  • Frequency
    9 kHz to 30 MHz
  • Inductance
    50 to 250 µH
  • Maximum Continuous Current
    300 to 500 A
  • Power Line Frequency
    DC to 60 Hz